Product description
Professional PC software, one-key reading of debugging parameters.
. The virtual oscilloscope diagnoses accurately and observes the data curve.
. Support 485 communication, SPI, GPRS, PG card, and other expansion interfaces.

. The book’s narrow-body structure saves up to 60% of the volume.
. New keyboard design, simple appearance, and easy operation.
. European-style terminals improve wiring efficiency.

SI23-D3 Series,DC150V-450V Input, 3 Phase 220-240VAc Output
Solar pump inverter power(KW):0.75kW |
Voltage: 220VAC, Current: 4A, Frequency: 0-320Hz |
Solar pump inverter power(KW):1.5kW |
Voltage: 220VAC, Current: 7A, Frequency: 0-320Hz |
Solar pump inverter power(KW):2.2kW |
Voltage: 220VAC, Current: 10A, Frequency: 0-320Hz |
Solar pump inverter power(KW):4kW |
Voltage: 220VAC, Current: 16A, Frequency: 0-
Input Power Supply
Voltage and frequency |
D1 model:90-400VDC/single-phase 110VAC 50/60HZ
D3 model:150-450VDC/ single-phase 220VAC 50/60HZ
D5 model:250-750VDC/ three-phase 380VAC 50/60HZ
T3 model:350-780VDC/ three-phase 380VAC 50/60HZ |
Allowable fluctuations |
Voltage imbalance rate:<3%
Frequency fluctuation:±5%
Distortion rate: Conform to IEC 61800-2 |
Frequency inverter efficiency |
≥96% |
Recommended voltage Voc |
D1 model:175-360VDC
D3 model:360-430VDC
D5 model:620-750VDC
T3 model:620-750VDC |
Output
MPPT efficiency |
reaches 99.9% |
Output frequency range |
0-320Hz (320 Hz or higher frequency can be customized) |
Overload capacity |
150% rated current 1min; 180% rated current 10s; 200% rated current 0.5s |
Protection Functions
Solar pump protection functions |
Dry protection, low frequency protection, minimum power protection, sleep protection, overwater protection, pump overcurrent protection, etc. |
Basic protection functions |
Overvoltage, undervoltage, inverter overcurrent, module fault, inverter overload, motor overload, current detection zero-drift fault, current detection fault, E2RCM fault, grounding short-circuit fault, input phase loss, output phase loss , inverter overheating, communication fault, motor parameter self-learning fault, etc. |
Short-circuit detection of motor grounding |
Automatic detection whether the motor is Short-circuit to ground in power-on |
Servo control |
Support synchronous and asynchronous servo control, perform pulse tracking, zero servo, indexing positioning and other basic servo functions, and support the orthogonal pulse given. |
Communication network |
Supports RS485 communication, to realize network and linkage control between VEICHI inverters |
Remote monitoring |
Supports remote program upgrade, data monitoring and lock function, can connect VEICHI GPRS module, and supports VEICHI virtual oscilloscope for monitoring and debugging |
Surroundings
Installation location |
Outdoor, less than 1000m altitude, keep away from corrosive air and direct sunlight |
Temperature and humidity |
-10-60°C, 20%-95%RH (no condensation) |
Vibration |
The vibration is less than 0.5g when the vibration frequency is less than 20Hz |
Storage temperature |
-20~60℃ |
Installation mode |
Suspension installation |
Protection class |
IP20 |
Cooling method |
Natural cooling/forced air cooling |
International Certification
International certification |
CE Standard Comformance:IEC 61800-3:2018, IEC 61000-3-2:2019
EN 61000-3-3:2013
EN 61800-5-1:2007+A1:2017 |
|
Reviews