Description
Solar pump inverter converts solar power (DC power) into AC power to drive AC water pump directly without solar panel
Smart:
Full automatic operation, no need programming, user-friendly
Modular design, easy install , operate & maintain
GPRS or SPMCS remote control for option
Efficient:
1:1 match to AC pumps with strong overload capacity
30% more water output with advanced inverter control algorithm
Maximum power point tracking (MPPT) efficiency reach 99% with advanced MPPT algorithm
Good ROI (Return on Investment) against diesel powered pumping
Solar Pump Inverter Specifications
Hober Solar Pump Inverter Model
|
HSPH5500H
|
HSPH7500H
|
|
Solar Panel DC Input
|
Max VOC Voltage
|
780V
|
|
Min VMP Voltage
|
400V
|
||
Recommend VMP Voltage
|
>500V ( Only Solar ) >560V ( Hybrid Power )
|
||
Max MPPT efficiency
|
99%
|
||
Max Input Current
|
14A
|
20A
|
|
Number of Strings
|
2
|
2
|
|
Inside Booster
|
N
|
||
Note
|
Automatic MPPT Function to Identify the VOC and VMP of Solar Panel, without Programming
|
||
Hybrid AC/Generator Input
|
Voltage
|
3 Phase 380/400/440V
|
|
Max Input Current
|
14A
|
19A
|
|
Hybrid Mode
|
Automatic, AC supplement automatic while solar is in low power mode and AC disconnect automatic while solar power recovery
|
||
AC output ( For Pump, Aerator, Fan )
|
Max Adapted AC Pump HP
|
7.5HP
|
10HP
|
Max Adapted AC Pump Power
|
5.5kW
|
7.5kW
|
|
Drive Mode
|
Variable Frequency Drive 3 Phase
|
||
Max Output Voltage
|
380/400/440V
|
||
Max Output Frequency
|
50~60Hz ( Support program range 15-60Hz)
|
||
Max Output Current
|
13A
|
18A
|
|
Max Efficiency
|
97%
|
||
Water Level Sensor (Well / Tank)
|
Yes
|
||
GPRS SMS Monitor & Controller
|
Optional
|
||
Display
|
LCD display
|
||
Waterproof
|
IP65
|
||
Noise
|
<50dB
|
||
Cooling Method
|
Force Cooling by Fan ( IP68 )
|
||
Protection
|
Solar DC Input Low/Over Voltage; Solar DC input Reverse Polarity; AC output Short-circuit; Over Temperature; Over Flow of Tank; Against Lightning; AC Input & Output Phase Lose; Dry-Run (detecting by Sensor or Software); AC output Unbalance
|
||
Operating Environment
|
Operating Environment Temperature
|
-10 to 60℃, Above 60℃ need to derate load
|
|
Max Humidity
|
95%RH
|
||
Using Altitude
|
<3000m, Above 300m need to derate load
|
||
Others
|
Prohibiting the installation location: direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid. etc.
|
||
Package
|
Size
|
550*350*285MM
|
|
Weight
|
15Kg
|
16Kg
|
Hober 5.5Kw Solar Water Pumping inverter Features

Reviews
There are no reviews yet.