Product description
Professional PC software, one-key reading of debugging parameters.
. The virtual oscilloscope diagnoses accurately and observes the data curve.
. Support 485 communication, SPI, GPRS, PG card, and other expansion interfaces.

. The book’s narrow-body structure saves up to 60% of the volume.
. New keyboard design, simple appearance, and easy operation.
. European-style terminals improve wiring efficiency.

SI23-D3 Series,DC150V-450V Input, 3 Phase 220-240VAc OutputSolar pump inverter power(KW):0.75kW | Voltage: 220VAC, Current: 4A, Frequency: 0-320Hz |
---|
Solar pump inverter power(KW):1.5kW | Voltage: 220VAC, Current: 7A, Frequency: 0-320Hz |
---|
Solar pump inverter power(KW):2.2kW | Voltage: 220VAC, Current: 10A, Frequency: 0-320Hz |
---|
Solar pump inverter power(KW):4kW | Voltage: 220VAC, Current: 16A, Frequency: 0-Input Power SupplyVoltage and frequency | D1 model:90-400VDC/single-phase 110VAC 50/60HZ
D3 model:150-450VDC/ single-phase 220VAC 50/60HZ
D5 model:250-750VDC/ three-phase 380VAC 50/60HZ
T3 model:350-780VDC/ three-phase 380VAC 50/60HZ |
---|
Allowable fluctuations | Voltage imbalance rate:<3%
Frequency fluctuation:±5%
Distortion rate: Conform to IEC 61800-2 |
---|
Frequency inverter efficiency | ≥96% |
---|
Recommended voltage Voc | D1 model:175-360VDC
D3 model:360-430VDC
D5 model:620-750VDC
T3 model:620-750VDC |
---|
OutputMPPT efficiency | reaches 99.9% |
---|
Output frequency range | 0-320Hz (320 Hz or higher frequency can be customized) |
---|
Overload capacity | 150% rated current 1min; 180% rated current 10s; 200% rated current 0.5s |
---|
Protection FunctionsSolar pump protection functions | Dry protection, low frequency protection, minimum power protection, sleep protection, overwater protection, pump overcurrent protection, etc. |
---|
Basic protection functions | Overvoltage, undervoltage, inverter overcurrent, module fault, inverter overload, motor overload, current detection zero-drift fault, current detection fault, E2RCM fault, grounding short-circuit fault, input phase loss, output phase loss , inverter overheating, communication fault, motor parameter self-learning fault, etc. |
---|
Short-circuit detection of motor grounding | Automatic detection whether the motor is Short-circuit to ground in power-on |
---|
Servo control | Support synchronous and asynchronous servo control, perform pulse tracking, zero servo, indexing positioning and other basic servo functions, and support the orthogonal pulse given. |
---|
Communication network | Supports RS485 communication, to realize network and linkage control between VEICHI inverters |
---|
Remote monitoring | Supports remote program upgrade, data monitoring and lock function, can connect VEICHI GPRS module, and supports VEICHI virtual oscilloscope for monitoring and debugging |
---|
SurroundingsInstallation location | Outdoor, less than 1000m altitude, keep away from corrosive air and direct sunlight |
---|
Temperature and humidity | -10-60°C, 20%-95%RH (no condensation) |
---|
Vibration | The vibration is less than 0.5g when the vibration frequency is less than 20Hz |
---|
Storage temperature | -20~60℃ |
---|
Installation mode | Suspension installation |
---|
Protection class | IP20 |
---|
Cooling method | Natural cooling/forced air cooling |
---|
International CertificationInternational certification | CE Standard Comformance:IEC 61800-3:2018, IEC 61000-3-2:2019
EN 61000-3-3:2013
EN 61800-5-1:2007+A1:2017 |
---|
|
---|