Description
Solar pump inverter converts solar power (DC power) into AC power to drive AC water pump directly without solar panel
Smart:
Full automatic operation, no need programming, user-friendly
Modular design, easy install , operate & maintain
GPRS or SPMCS remote control for option
Efficient:
1:1 match to AC pumps with strong overload capacity
30% more water output with advanced inverter control algorithm
Maximum power point tracking (MPPT) efficiency reach 99% with advanced MPPT algorithm
Good ROI (Return on Investment) against diesel powered pumping
Solar Pump Inverter Specifications
Hober Solar Pump Inverter Model | HSPH5500H | HSPH7500H | |
Solar Panel DC Input | Max VOC Voltage | 780V | |
Min VMP Voltage | 400V | ||
Recommend VMP Voltage | >500V ( Only Solar ) >560V ( Hybrid Power ) | ||
Max MPPT efficiency | 99% | ||
Max Input Current | 14A | 20A | |
Number of Strings | 2 | 2 | |
Inside Booster | N | ||
Note | Automatic MPPT Function to Identify the VOC and VMP of Solar Panel, without Programming | ||
Hybrid AC/Generator Input | Voltage | 3 Phase 380/400/440V | |
Max Input Current | 14A | 19A | |
Hybrid Mode | Automatic, AC supplement automatic while solar is in low power mode and AC disconnect automatic while solar power recovery | ||
AC output ( For Pump, Aerator, Fan ) | Max Adapted AC Pump HP | 7.5HP | 10HP |
Max Adapted AC Pump Power | 5.5kW | 7.5kW | |
Drive Mode | Variable Frequency Drive 3 Phase | ||
Max Output Voltage | 380/400/440V | ||
Max Output Frequency | 50~60Hz ( Support program range 15-60Hz) | ||
Max Output Current | 13A | 18A | |
Max Efficiency | 97% | ||
Water Level Sensor (Well / Tank) | Yes | ||
GPRS SMS Monitor & Controller | Optional | ||
Display | LCD display | ||
Waterproof | IP65 | ||
Noise | <50dB | ||
Cooling Method | Force Cooling by Fan ( IP68 ) | ||
Protection | Solar DC Input Low/Over Voltage; Solar DC input Reverse Polarity; AC output Short-circuit; Over Temperature; Over Flow of Tank; Against Lightning; AC Input & Output Phase Lose; Dry-Run (detecting by Sensor or Software); AC output Unbalance | ||
Operating Environment | Operating Environment Temperature | -10 to 60℃, Above 60℃ need to derate load | |
Max Humidity | 95%RH | ||
Using Altitude | <3000m, Above 300m need to derate load | ||
Others | Prohibiting the installation location: direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid. etc. | ||
Package | Size | 550*350*285MM | |
Weight | 15Kg | 16Kg |
Hober 5.5Kw Solar Water Pumping inverter Features

Reviews